Ann sets up Anristu MS9740A spectrum analyzer MS9740A

 

Ann sets up Anristu MS9740A spectrum analyzer

Tan YanFei ( General manager) –S Jiang (specially help)



MS9740A spectrum analyzer, shortening scanning from the waveform to the whole testing time for data transmission to the external control equipment by a wide margin, and simplify and analyze the step, have very good cost performance, will make contributions to the improvement of production efficiency.
Under 0.2 second /test, 5nm speed, last time where the active devices analyze.
Allocate the application software used for specially commenting on the mere active device.
Spanking cost performance
Dynamic range characteristic above 58dB (from the place of the peak wavelength 0.4nm)
Minimum resolution of 30pm
A corresponding SM optic fibre, MM optic fibre Low power consumption ( 75V) , light (under 15kg)
MS9740A is that Ann sets up the new desk-top spectrum analyzer put out. Researching and developing the large dynamic range of MS9710C/MS9780A that the field is being used extensively for a long time in the past, on the high-performance basic characteristic foundation of optics that high-resolution,etc. is headed by, further improve the characteristic, have realized the high-speed test function required on the production line of mere active device strongly. Analytic from scanning in waveform to the waveform and data transmission to the external control equipment, have realized whole test speed under the short 0.2 seconds the most. Compared with type in the past, it is tested that the speed is 5 fold, namely test 1/5 of the time when only took in the past too.
To producer of the mere active device, it cuts down headed by optical transcreceiving module the intersection of device and production cost to be pieces of important subject. To the device tests the required test instrument, expect to be able to realize efficient appraisal tests to shorten testing time.
MS9740A spectrum analyzer, shortening scanning from the waveform to the whole testing time for data transmission to the external control equipment by a wide margin, and simplify and analyze the step, have very good cost performance, will make contributions to the improvement of production efficiency.
Applicable optic fibre 10¦Ì m/ 125¦Ì m SM optic fibre (ITU-T G.652) ,50¦Ì m/ 125¦Ì m GI optic fibre
The users swappable FC of optical connector, SC, ST, DIN, LC
Test the wavelength range 600nm – 1750nm
Wavelength precision *1 ¡À 20pm (1520nm -1620nm, dissociation energy: 0.03 to 0.2nm) *2,
¡À 100pm (1520nm -1620nm, dissociation energy: 0.5,1.0nm) *2
Wavelength definition 0.03, 0.05, 0.07, 0.1, 0.2, 0.5, 1.0nm (RBW: 3dB passes the bandwidth)
Maximum inputs the luminous power +23dBm (mere ATT: On)
Dynamic range *A high dynamic range: 60dB (from the place of the peak wavelength 0.4nm)
Ordinary dynamic range: 58dB (from the place of the peak wavelength 0.4nm)
[Definition: 0.05nm, 1550nm, mere Att: Off, 20-30 ¡æ]
Scan the wavelength run-length: 0.2nm to 1200nm, 0nm
Scanning speed: ¨Q 0.2sec. (span 5nm) ,
[Definition: 0.1nm, VBW =10kHz, ordinary dynamic range mode, central wavelength 1550nm,
From sweep start to end, there is no light input, sampling points: pound; 501]
Size # 12539; Weight 426 (W) x 177 (H) x 350 (D) Mm (excluding the protector) ,¨Q 15.0kg (excluding the option)
*1: Use SM optic fibre (ITU-T G.652) , after the starting up is preheated for 2 hours
(While preheating, carrying on under Span100nm, VBW =Repeated sweep above 10kHz)
*2: The built-in wavelength corrects and uses the option of light source, implements the wavelength and corrects Wl cal (ref) And then, when temperature must



Contacts: Tan YanFei
Telephone: 86075521502766
Fax: 860755-21502766
Email: yixin1718@126.com
Web site: http://www.yqybshop.com
Address: Shenzhen the intersection of Medulla Junci and the intersection of newly developed area and the intersection of Chinese pine and the intersection of way and it remit of 408, A of mansion,